Reporting for zinc at Protec Finishing

Comparison of tracking and quantification.

 REPORTING FOR ZINC AT PROTEC FINISHING

 

QUANTITY (Tonnes)

PERCENTAGE CHANGE

 

2015

2014

CHANGE

 

ENTERS FACILITY - USE

100 - 1000

100 - 1000

1 - 10

Increase of 2%

CREATION

0

0

0

n/a

CONTAINED IN PRODUCT

100 - 1000

100 - 1000

10 - 100

Increase of 11%

 

Reasons for change – quantities are approximately the same.   

How the facility has reduced the amount of the substance that is used – quantity of the substance has not been reduced.   

How the facility has reduced the amount in product - quantity of the substance in product has not been reduced.

Update on timelines.

7.0       Implementation of Options for Reduction of Zinc.  

To reduce the use of zinc at the facility, Protec Finishing has plans to implement the following options:  

No options were identified as being technically and economically feasible

 


 Reporting for hydrochloric acid at Protec Finishing:

Comparison of tracking and quantification.

 REPORTING FOR HYDROCHLORIC ACID AT PROTEC FINISHING

 

QUANTITY (Tonnes)

PERCENTAGE CHANGE

 

2015

2014

CHANGE

 

ENTERS FACILITY - USE

100 - 1000

100 - 1000

1 - 10

Decrease of 8%

CREATION

0

0

0

n/a

CONTAINED IN PRODUCT

0

0

0

n/a

 

Reasons for change – Quantities approximately same.  

How the facility has reduced the amount of the substance that is used – quantity of the substance has been reduced.  

How the facility has reduced the amount in product – substance is not present in the product.

 Update on timelines.

 7.0       Implementation of Options for Reduction of hydrochloric acid.

To reduce the use of hydrochloric acid at the facility, Protec Finishing has plans to implement the following options:

 Table 8. Description and Timetable for Implementation of Steps of Option # 3

Table 8. Description and Timetable for Implementation of Steps for Equipment or process modification Option.

INCREASED DRAIN TIME PRIOR TO THE PICKLE TANK TO REDUCE DRAG IN WATER. INCREASED DRAIN TIME OVER THE PICKLE TANK TO RECOVER MORE OF THE SOLUTION LOST THROUGH DRAG OUT

Step

Description

Estimated timelines

1

Determination of amount of additional time required to achieve a 25% reduction in drag out on the Lake line and Enterprise line

Mar 31, 2013

 

It was determined that an additional two minutes of drain time would be required to reduce the drag out by 25%

Completed April 26, 2013.

2

Evaluation on the effect of production of using the increased dwell times on the Lake line and Enterprise line

June 30, 2013

 

It was determined that increasing the drain time by an additional two minutes would have a significant adverse effect on the productivity of the production line making it economically unfeasible to implement.

Completed May 2, 2013.

3

Programming of PLC computers with additional dwell times.

Dec 31, 2013

 

Option will not be implemented as the effect on production makes it economically unfeasible to implement.

Completed May 2, 2013.

 

 

 

 


 

Reporting for nitric acid at Protec Finishing:

 Comparison of tracking and quantification.

 REPORTING FOR NITRIC ACID AT PROTEC FINISHING

 

QUANTITY (Tonnes)

PERCENTAGE CHANGE

 

2015

2014

CHANGE

 

ENTERS FACILITY - USE

10 - 100

10 - 100

1 - 10

Decrease of 9%

CREATION

0

0

0

n/a

CONTAINED IN PRODUCT

0

0

0

n/a

 

Reasons for change – Quantities approximately same.  

How the facility has reduced the amount of the substance that is used – quantity of the substance has been reduced.  

How the facility has reduced the amount in product – substance is not present in the product.

 Update on timelines.

 7.0       Implementation of Options for Reduction of nitric acid.  

To reduce the use of nitric acid at the facility, Protec Finishing has no plans to implement any options to reduce the use

of nitric acid at Protec Finishing as no technically and financially feasible options were identified.

Back